Operating Specifications 1.Operating Ambient Temperature: -40°C --- +60°C 2. Relative Humidity: 10% - 90% RH 3. Vibration 1.0mm, 10 –25Hz, 15 minutes per cycle for each axis (X, Y, Z) Input 1 AC input range: 90-260Vac/0.5 A max /50-60Hz 2 Input inrush current: ≤10A at 110Vac ≤20A at 230Vac 3 Power factor: ≥0.95 at full load,115Vac/230Vac 4 Efficiency: >92% Typical Output 1 Ripple and Noise Maximum peak to peak ripple & Noise<output voltage 5% Measurements are taken with a 20MHz bandwidth oscilloscope and each out put terminated with a 10uF capacitor and a 0.1uF capacitor. 2 Output current precision: Io±5%